Integration:
System Interface Products replace what is
normally a mélange of separate devices with
integrated systems manufactured specifically for
the satellite industry. All SIP units are
rack mountable, and act to reduce the mess of
cables at the back of the rack. Product
integration results in greater quality, vastly
improved reliability, much less signal loss,
properly matched components, and lowered overall
costs, especially when the costs to source,
assemble, and test a 'kluge' are considered.
|
 |
Multiplexers for
Terrestrial Satellite Systems
|
Application
|
J-1
|
J-2
|
J-3
|
J-4
|
J-5
|
Orbital Product
|
|
Bias Tee |
L, DC |
L |
DC |
plug |
N/A |
MT25/40 Mux Tee |
|
Mux Tee |
L,
DC, 10 |
L |
DC |
10 |
N/A |
MT25/40 Mux Tee |
|
Diplexer |
L, 10 |
L |
plug |
10 |
N/A |
MT25/40 Mux Tee |
| 10
Mhz Thru Tee |
L,
DC, 10 |
L,
10 |
DC |
plug |
N/A |
TT25/40 Thru Tee |
| DC
Thru Tee |
L,
DC, 10 |
L,
DC |
plug |
10 |
N/A |
TT25/40 Thru Tee |
| 10
MHz Extractor |
L,
DC, 10 |
L,
DC, 10 |
DC |
10, -3 |
N/A |
ERT25/40 Extractor Tee |
| DC
Extractor |
L,
DC, 10 |
L,
DC, 10 |
DC
in |
DC
out |
N/A |
ETT25/40 Extractor Tee |
|
Redundant DC Tee |
L,
DC, 10 |
L,
10 |
DC
in |
DC
in |
N/A |
RPT Redundant Power Tee |
|
Redundant Power Module |
DC
out |
DC
out |
DC
in |
DC
in |
N/A |
RPM Redundant
Power Module |
|
433 Mux Tee |
L,10,DC,433 |
L |
DC |
10 |
433 |
MT433 Mux Tee |
| |
|
|
|
|
|
|
|
System Interface
Products
| Models |
Product |
|
|
|
|
|
 |
Bias Tee (use
Orbital MT25/40 Mux Tee) Insert or
extract DC power to or from the
combined signal (IFL).
|
 |
 |
 |
Mux/Tee
Insert or
extract 10 MHz or DC power to or
from the combined signal.
|
 |
 |
 |
Diplexer
Combine 10 MHz output
with L-Band feed to an LNB or a BUC
|
 |
 |
 |
10 MHz Extractor
Thru Tee
Pass L band, 10
MHz and DC to the LNB, BDC or BUC,
extract 10 MHz reference signal at the dish to supply
additional devices without re-cabling |
 |
 |
 |
DC Extractor Thru Tee
Pass L band, 10
MHz and DC to the LNB, BDC or BUC,
extract DC power at the dish to supply
another device without re-cabling
|
 |
 |
 |
Thru Tee
Bias Tee with L band and 10 MHz
Pass-Through
|
 |
 |
 |
Redundant Power
Module
Has two inputs,
one for each power supply, and simply
uses the power supply with the highest
voltage. So if one fails, it
switches to the other device. Has
two DC outputs to provide redundant
power to two devices.
|
 |
 |
 |
Redundant Power Tee
Bias Tee with dual power supplies that
switch automatically on power supply
failure. The least expensive
redundancy option! |
 |
 |
 |
433 MHz Mux Tee
433 MHz Monitor and Control Channel in
addition to Insert or
extract L band, 10 MHz or DC power to or
from the combined signal. Used
in conjunction with the Orbital 433 MHz
Modem.
|
 |
 |
|
|
|
|